Benvenuto sul sito Italiano

Abbiamo rilevato che potresti preferire il sito United Kingdom. Se necessario, utilizza il menu a tendina delle lingue per modificare la scelta.

Go to United Kingdom

Understanding Furnace controls

A zirconia probe is used to measure very low concentrations of % oxygen in the furnace, typically less than 1 x 10 -20. To supply the required species carbon it is usual for the furnace to be supplied with a base endothermic carrier gas which conditions the furnace, at say 20% CO for a methane based carrier gas.

In the atmosphere loop, the controller uses the carbon potential calculation based on the known oxygen reading to increase the carbon potential by allowing enrichment gas (ie methane) to enter the furnace.

Conversely, to decrease the carbon potential, controlled air is introduced into the furnace. Automatic probe cleaning functions ensure that the reading is accurate, while probe health and sooting alarms warn of a deterioration in the probe performance.

Strumento di selezione dei prodotti

Package icon
Hai bisogno di aiuto per scegliere il prodotto giusto?

Il nostro strumento ti aiuterà a trovare il prodotto più adatto alle tue esigenze

Accedi allo strumento di selezione dei prodotti

Contattaci

close
close