한국유로썸 홈페이지에 오신 것을 환영합니다.

한국유로썸의 홈페이지로 연결 되었습니다. 다른 언어로 보고싶으신 경우 상단의 선택바를 사용하여 언어를 변경하십시오

Go to United Kingdom

Compliance to environmental regulation is now required for any industrial activity. There are very few activities that have zero environmental impact at all. Most work produces waste, burns fuel, uses electricity or carries some risk of pollution.

The Eurotherm Environmental Monitoring System aims at helping to achieve a rigorous approach to managing and improving the environmental aspect of operations required by the ISO 14001 international standard for environmental management systems.

In order to achieve this, the Eurotherm EMS application module provides you with the information and functionality needed to capture the system behaviour and make environmental investment effective.

EMS application module functions

  • Normal, maintenance and calibration operation modes
  • Analogue or digital input type
  • Retention of last good value and calculation of a confidence factor if an input fails
  • Variable sampling time
  • Maximum and minimum PV history
  • Totalisation
  • Running average calculation
  • External reset request of historical data
  • Alarm functionality and re-alarming after a preset time

EMS front-end applications

  • Selection of tags to average
  • Selection of date/time limits focusing on specific time intervals in each day or including all the samples between the date boundaries (see picture)
  • Up to three averages calculated at the same time on different time intervals (ranging from minutes to months) on the same group of tags (see Example 1)
  • Up to three groups of tags averaged at the same time, each one associated with a different average time interval (see Example 2). This functionality is used to compare actual averages against the maximum authorised average associated to specific monitoring points
  • Textual description of the current settings before the calculation begins in order for the operator to check if the report will meet his expectations
  • Ability to pause the calculations, view partial reports and restart at a later time or stop the routine
  • Ability to print sub-reports including averages from a narrower time interval
  • Ability to merge backup files in order to calculate averages over the backup time
  • Ease of customisation to meet specific requirements

Example 1
On all selected monitoring points calculate:
Avg 1: every 30 mins
Avg 2: every day
Avg 3: every week

Example 2
On monitoring point 1, calculate average every 2 hours
On monitoring point 2, calculate average every 3 days
On monitoring point 3, calculate average every 15 days

Product Selector

Package icon
Need help choosing the right product?

Our tool will match the best product to your needs

Launch product selector

Contact Us

close
close