7200A Two leg, three phase Power Controller
7200A Two leg, three phase Power Controller
Ideal for:
- Glass lehrs
- Heat treatment – metal furnaces
- Plastics
- Ceramic furnaces
- Semi-conductor manufacture
- Ovens
- Thermo-forming
- SWIR heaters
Description
- Current range from 16 to 200A at 45°C
- Voltage up to 500V
- Input current 0-20mA or 4-20mA
- Input voltage 0-5V or 0-10V
- Firing modes: Burst, single cycle
- Thyristor short circuit alarm
- Load open circuit alarm
- Partial load failure detection
- Thyristor over-temperature alarm
Two leg, three phase thyristor units for use with short wave infrared (SWIR) or resistive loads. The units consist of two thyristor controlled channels each rated at the specified current and voltage.
Firing Modes
The 7200A is available with a selection of firing modes to suit most three phase applications with resistive elements in 3-wire configuration. It is suitable for controlling resistive loads with low temperature coefficient and short wave infrared (SWIR).
Alarms
Optional alarms can warn of thyristor short circuit or load open circuit. It includes partial load failure with automatic set up which can detect the loss of at least one for up to four parallel loads (DLF).
Over temperature shutdown is provided with fan cooled units with optional alarm.
Fusing
High speed fuses are recommended for most applications except SWIR. Fuses are available either with or without microswitch indication.
Specification
Digital Comms | None |
---|---|
True-power-control | No |
Maximum Current (Amps) | 200A |
Maximum Voltage (Volts) | 500V |
Controlled Phases | 2 |
PLF and/or PLU | Yes |
Current Limit | No |
Diagnostics | Yes |
Alarm Types | ja |
Input Analogue | Yes |
Input Logic | Yes |
Firing Mode Phase Angle | No |
Firing Mode Burst Firing | Yes |
Heater Type Constant Resistance | Yes |
Heater Type SWIR | Yes |
Heater Type Variable Resistance | No |
Heater Type Inductive/Transformer Coupled | No |