Need help choosing the right product?
Our tool will match the best product to your needs
Launch product selectorWelcome to the USA Website
We have detected that you may prefer the United Kingdom site. Please use the language dropdown above to change your selection if required.
Vulcanisation is a process that is performed to harden rubber and improve its strength. The process, which is performed within an autoclave, is a function of temperature and time.Typical applications include automotive tyres, rubber mats and Wellington Boots. Vulcanisation includes the temperature profiling of both temperature and pressure. Traditionally, in most applications there is no indication of when the cure is complete. For this reason, to ensure that all components in the autoclave have been universally cured, process cycle times are usually longer than is necessary.
Temperature and pressure are both controlled by a 2604 programmer. The temperature control sensor is situated in free air and the control output can either drive a thyristor or a contactor.
Forcing air into or out of the autoclave using solenoid valves controls the pressure. The 2604 ToolKit functions are used to totalise the elapsed cure time and provide process interlocks.
This particular application involved the curing of the adhesive, which bonds the retread to the original tyre. A dummy load(rubber block)is placed inside the autoclave which emulates the temperature rise being achieved in the tyre. This load is placed in the coolest area of the autoclave. A sensor is inserted into the load and used by the controller to calculate the equivalent cure minute(ECM) value. When the total ECM’s reach a preset level, the curing cycle is complete.
The formula the 2604 needs to calculate is as follows:-
The ECM value is totalised every minute to produce a sum of the cumulated ECM’s. When the totalised value gets to its preset value a relay output is generated.
Product Selector
Our tool will match the best product to your needs
Launch product selectorContact Us